Skip to content
A&DWARNERPassive Fire Protection
Our services

Passive Fire Protection Services

Spray-applied fireproofing and passive fire protection services for commercial construction projects across Sydney and NSW — delivered by an experienced, safety-focused subcontractor.

Structural Steel Fireproofing — spray-applied fireproofing in NSW
01

Structural Steel Fireproofing

A&D Warner applies spray-applied fire protection to structural steel on commercial construction projects across Sydney and NSW. We work to the fire-resistance levels nominated in the project specifications and fire engineering requirements, applying cementitious fireproofing systems — including CAFCO 300 — to beams and ductwork at consistent, specified thickness using professional Immer spray pumps.

  • Spray application to structural steel beams and ductwork
  • Application to specified fire-resistance levels (FRLs)
  • Surface preparation and protection of adjoining work areas
  • Thickness checking throughout application
  • Photographic records and QA documentation
  • Coordination with builders, steel erectors and other trades
Service details
CAFCO 300 — spray-applied fireproofing in NSW
02

CAFCO 300

A&D Warner is experienced in the application of CAFCO 300 spray-applied fireproofing on commercial projects across NSW. We apply CAFCO 300 with Immer spray pumps in accordance with manufacturer requirements and project specifications, with thickness checks and photographic QA records provided throughout the works.

  • CAFCO 300 application to structural steel
  • Application in line with manufacturer requirements
  • Thickness testing to specified fire-resistance levels
  • Photographic QA records during application
Service details
Perlifoc HP — spray-applied fireproofing in NSW
03

Perlifoc HP

We undertake Perlifoc HP application for commercial construction projects in Sydney and across NSW, installed in accordance with project specifications and manufacturer requirements. Our crews are experienced with spray-applied perlite-based fireproofing systems across structural beams and ductwork.

  • Perlifoc HP application to structural steel
  • Application to project specifications and FRL requirements
  • Manufacturer-compliant installation methods
  • Thickness checking and QA records
Service details
Fendolite & PSK Systems — spray-applied fireproofing in NSW
04

Fendolite & PSK Systems

A&D Warner applies Fendolite and PSK passive fire protection systems on commercial construction projects across NSW. Our team works with the major spray-applied fireproofing systems specified on Australian commercial projects, applied in accordance with manufacturer requirements and project documentation.

  • Fendolite system application
  • PSK system application
  • Application to manufacturer specifications
  • Thickness testing and QA documentation
Service details
Fire-Rated Duct Protection — spray-applied fireproofing in NSW
05

Fire-Rated Duct Protection

We provide passive fire protection for ductwork and associated construction elements on commercial projects across Sydney and NSW. Fire-rated duct and service protection is applied in accordance with the project specifications, fire engineering requirements and manufacturer documentation for the nominated system.

  • Fire protection to commercial HVAC ductwork
  • Application to specified fire-resistance levels
  • Work in ceiling voids and plant areas
  • Protection and preparation of work areas
Service details
Repairs & Rectification — spray-applied fireproofing in NSW
06

Repairs & Rectification

Damaged, incomplete or non-compliant fireproofing is a common issue on active commercial sites. A&D Warner undertakes repairs, reinstatement and rectification of existing passive fire protection — from impact and follow-on trade damage through to incomplete or failed applications that need to be brought up to specification.

  • Repairs to damaged spray-applied fireproofing
  • Reinstatement after follow-on trade damage
  • Rectification of incomplete or failed applications
  • Existing fireproofing repairs on refurbishment projects
Service details
Additional Thickness & Upgrade Works — spray-applied fireproofing in NSW
07

Additional Thickness & Upgrade Works

Where inspections, revised fire engineering or updated specifications call for additional fireproofing thickness, A&D Warner can prepare and apply additional material to bring elements up to the required fire-resistance level. We undertake upgrade works on both new construction and existing buildings across NSW.

  • Additional thickness application to existing fireproofing
  • Upgrade works following inspections or revised fire engineering
  • Thickness testing to specified fire-resistance levels
  • Photographic and project QA documentation
Service details
QA & Project Documentation — spray-applied fireproofing in NSW
08

QA & Project Documentation

A&D Warner provides thorough QA and project documentation for spray-applied fireproofing works, including thickness checks, photographic records and written documentation to support handover. Records are produced as works progress so documentation matches the delivered application.

  • Thickness checks across the works
  • Photographic QA records during application
  • Project-specific QA documentation
  • Handover-ready records for builders and fire engineers
Service details
Upper commercial floor plate with spray-applied fireproofing on structural beams

Have a Project That Requires Passive Fire Protection?

Talk to A&D Warner about your upcoming project, fireproofing requirements or passive fire protection scope.

Request a Quote